The current page does not exist in the target language.

Do you want to change the language and go to the home page or do you want to stay on the current page?

Change Language
Solar Energy
Installers & partners

Fronius Symo GEN24

Inverters for private photovoltaic systems with backup power function

Our three-phase Fronius GEN24 inverter is the heart of private photovoltaic systems.
The Fronius GEN24 is equipped with PV Point, an integrated basic backup power function that supplies backup power to connected devices via a protected socket (as long as the sun is shining).*
 
The Fronius Symo GEN24 boasts a wide range of features that support a sustainable, independent energy supply. Discover the key features for installers and their customers:
 
/ Intelligent energy management
/ Active cooling for a longer service life
/ Flexible and fast installation
/ Easy integration and management of Fronius or third-party components thanks to open interfaces 
 
*The Full Backup option is not available for the Fronius Symo GEN24 3.0-5.0.
Please choose your desired product.

Product details

Input Data

Number of MPP trackers2
Max. input current (Idc max)
12,5 A / 12,5 A
Max. short circuit current, module array*
20,0 A / 20,0 A
DC input voltage range (Udc min - Udc max)
80-1000 V
Feed-in start voltage (Udc start)
80 V
Nominal input voltage (Udc,r)
610 V
MPP voltage range (Umpp min - Umpp max)
125-800 V
Usable MPP voltage range80-800 V
Number of DC connections2+1
Max. PV generator power (Pdc max
4,5 kWpeak

Output Data

AC nominal output (Pac,r)
3000 W
Max. output power (Pac max)
3000 VA
Max. grid power demand10 VA
Max. AC output current8 A
Grid connection (Uac,r)
3~NPE 230V / 400V, 3~NPE 220V / 380V
AC voltage range (Umin - Umax)
154-280 V
Frequency (fr)
50 / 60 Hz
Frequency range (fmin - fmax)
45-66 Hz
Total harmonic distortion<3% @Pnom (230/400VAC 50Hz)
Power factor (cos φac,r)
0,7-1 ind./cap.
Back-up power1 ~ NPE 220 V / 230 V
Nominal AC output current (380VAC)4,5 A
Nominal AC output current (400VAC)4,3 A

Output Data PV Point

Max continuous output power3000 VA
Nom. output current (Iac max)
13 A
Grid connection1 ~ NPE 220 V / 230 V
Nominal operating frequency50 Hz / 60 Hz
Max. switchover time PV-Point15 s
Frequency in backup power mode53 Hz

General Data

Width474 mm
Height530 mm
Depth165 mm
Weight15,61 kg
Weight incl. packaging19,35 kg
Protection classIP66
Protection class1
Overvoltage category (DC / AC) 1)
2/3
Night-time consumption<10 W
Inverter designTransformerless
CoolingActive Cooling
InstallationIndoor and outdoor installation
Ambient temperature range-25 - +60°C
Permitted humidity0 - 100%
Max. altitude3000m / 4000m
DC PV connection technology3x DC+ and 3x DC- push-in spring terminals 2.5 - 10 mm²
AC connection technology5 pole AC push-in spring terminals 1.5 - 10 mm²
3 pole backup power push-in spring terminals 1.5mm² - 10mm²
5x PE-screw terminals 2.5 - 16 mm²
Certificates and compliance with standardsIEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE 0126,
VDE AR-N4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G98/G99, R25​4)
Back-up power functionsPV Point
Sound emissions36 dB(A)
Interference emission classB

Efficiency

Max. efficiency (PV - grid)98,1 %
European efficiency (ηEU)96.7%
η at 5% Pac,r 3)
86.8%
η at 10% Pac,r 3)
92.4%
η at 20% Pac,r 3)
95.7%
η at 25% Pac,r 3)
96.3%
η at 30% Pac,r 3)
97.0%
η at 50% Pac,r 3)
97.6%
η at 75% Pac,r 3)
97.9%
η at 100% Pac,r 3)
98.1%
MPP adaptation efficiency99.9%

Protection Devices

DC insulation measurementYes
Overload behaviourOperating point shift,  Power limitation
DC disconnectorYes
DC Reverse polarity protectionYes

Interfaces

WLAN / 2x Ethernet LANFronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6x digital in/out + 6x digital inInterface to ripple control receiver, energy management
Emergency stop (WSD)Yes
Datalogger and web serverIncluded
2x RS485Modbus RTU SunSpec (third-party supplier) / Fronius Smart Meter, battery, Fronius Ohmpilot
The hybrid functions battery connection and full backup can be retrofitted to the GEN24 by Fronius UP.storage*!
*Fronius UP.storage can only be implemented in countries with Fronius Webshop. You can find an overview here.
More information about the features & availability of this product
Clear HTML version of the operating instructions. Mobile and optimised  for every device.
Information for installation and commissioning

Downloads

Show all downloads for product

Footnotes for technical data

1) According to IEC 62109-1. Option to retrofit surge protection device DC SPD type 1+2 for 2 MPP trackers available under the following item number: 4,240,313,CK 

2) Unrestricted / restricted voltage range.

3) At Udc,r

4) You can find the current certificates under www.fronius.com/symo-gen24-plus-cert

 

  * Isc pv = Isc max ≥ Isc (STC) x 1,25 according to e.g..: IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.